Skip to main content

Vibrafloor

Vibrafloor technology

How it works

Gravity and vibration.
Automatic discharge and final clean-out.

A pile of bulk material, regardless of its size, rests on a floor. If it loses its grip on that floor, it collapses. This is the principle behind Vibrafloor: destabilising the pile by transmitting vibration energy to its base.

This animation shows the automatic discharge sequence, from initial gravity flow through to complete emptying and final floor clean-out.

The automatic discharge cycle

From gravity flow
to complete emptying.

The Vibrafloor system works with gravity by transmitting controlled vibrations to the bulk material. These vibrations do not damage the storage structure. They destabilise the residual pile left after gravity discharge and move the material towards the outlet, leaving the storage facility completely empty.

01

Gravity discharge

At the end of the gravity discharge phase, Vibrafloor starts automatically when it detects the absence of material in the discharge hopper.

02

Sequential activation

Row by row, starting at the outlet and moving up the slopes, the sensors detect the absence of material and send a signal to the programmable logic controller (PLC). The PLC activates the corresponding modules to discharge the next layers of material.

03

Complete emptying

Layer by layer, the residual pile is progressively discharged until the last sensor, near the storage wall, is uncovered. The system continues for a short delay to complete emptying and clear the floor of residual material, then shuts down automatically, ready for the next discharge cycle.

The vibrating floor

A simple concept.
A modular system.

This simple concept is reflected in the design of the module, the basic building block of the vibrating floor. Each module combines a vibrating plate and a vibrator mounted on a rigid, sealed chassis.

In practice, the storage floor has a slope of between 10° and 20°, depending on the required discharge rate. The slope is fully covered with modules, each equipped with a vibrator. The modules are activated sequentially from bottom to top until all the material has been discharged. Capacitive sensors provide the signals that control their activation, acting as the eyes of the system.

Plate dynamics in vibration

Conical discharge (one outlet)

The Vibrafloor technology has been patented for many years in most areas of the world, and it continues to evolve every day.